ZRT512E-R454B & R32 NDIR Refrigerant Detection Module, RS485 HVAC Sensor, UL/IEC Certified
0 出来 5
ZRT512E-R454B&R32 series is an intelligent NDIR refrigerant detection module for R454B&R32 gases, with RS485 protocol, high sensitivity and long service life >15 years, ideal for HVAC systems.
类别: R454B制冷剂泄漏传感器,,,, R32制冷剂泄漏传感器
- 描述
- 附加信息
- 评论(0)
描述
The ZRT512E-R454B&R32 series is an intelligent infrared-based refrigerant detection module (hereinafter referred to as the module). It uses the Non-Dispersive Infrared (NDIR) principle to detect refrigerants, featuring good selectivity and no oxygen dependence. This compact and high-performance module combines mature infrared absorption gas detection sensors with micro machining and sophisticated circuit design, making it easy to use and delivering excellent performance.
产品特点
- 高灵敏度、高分辨率、响应时间快
- RS485协议,通讯稳定
- 内置温度补偿,优异的线性输出,稳定性突出,使用寿命长
- 抗水汽干扰,无中毒风险
- 可直接替代催化燃烧原理模块
产品应用
- 供暖、通风和空调 (HVAC)
- 制冷系统和热泵
- 工业过程监控
- 工业过程及安全防护监控
规格表
表 1 – 主要规格
| 物品 | 规格 |
|---|---|
| 型号 | ZRT512E-R454B&R32-4-A-S ZRT512E-R454B&R32-4-A-L |
| 目标气体 | R454B & R32 |
| 工作电压 | 5±0.5VDC,纹波<50mV |
| 平均电流 | <150mA@5V |
| 峰值电流 | <150mA@5V |
| 电缆长度 | 1.5m/3.2m |
| 接口方法 | XHS-4Y / XHS-5Y |
| 协议 | RS485,数据更新1s |
| 预热时间 | >30秒 |
| 响应时间① | ≤15秒 |
| 恢复时间② | ≤300秒 |
| 选择性测试恢复时间③ | ≥1小时 |
| 报警点 | 10%LFL (R454B) & 7%LFL (R32) |
| 工作状态 | -40~95℃,0-95%RH(无凝露),80-110kPa |
| 储存条件 | -40~70℃, 0-95%RH (无凝露) |
| 方面 | 54.0×49.1×17.9毫米 |
| 寿命 | >15年 |
| 认证 | UL 60335-2-40:2022 IEC 60335-2-40:2022 |
表 2 – 检测性能
| 目标气体 | 检测范围 | 解决 | 准确性 |
|---|---|---|---|
| Refrigerant R454B&R32 | 0〜100%lfl | 0.1%LFL | ±2.5%LFL(@0%~25%LFL) ±5%LFL(@25%~50%LFL) |
笔记
Tested according to UL 60335-2-40:2022 & IEC 60335-2-40:2022
① 响应时间
② 清洁空气中传感器从 25% LFL 恢复到初始值(<2.5% LFL)的时间(T10)
③ 选择性测试时两次干扰气体测试的间隔时间
附加信息
| 检测气体 | R32、R454B |
|---|---|
| 原则 | 是n |
| 产品类型 | 模块 |
| 输出 | RS485 |





评论