Infrared Refrigerant Leak Sensor (NDIR) — PPM Early Warning & %LEL Safety
Winsen® infrared (NDIR) refrigerant leak sensors provide stable, selective measurement for A1, A2L, and A3 gases—R134a, R410A, R32, R454B, R1234yf/ze, R290, R600a. Choose ppm-level accuracy for early warning, or %LFL/%LEL for safety interlocks. Seamless BMS/PLC integration via 4–20 mA, RS-485 Modbusin relejni izhodi.


Why Infrared (NDIR) for Refrigerant Leak Detection?
High Selectivity
NDIR measures gas absorption at specific IR wavelengths, delivering excellent selectivity for HFC/HFO refrigerants and robust A2L/A3 options.
Stability & Low Drift
Dual-channel optical design with reference beam minimizes temperature/ageing drift, extending calibration intervals (often 12–24 months).
Not O₂-Dependent
Infrared sensing does not require oxygen, unlike catalytic beads—ideal for machinery rooms, cold rooms, and enclosed HVAC spaces.
Model Guide — Select by Class & Measurement
Infrared (NDIR) refrigerant leak sensors and detectors for A1, A2L, and A3 gases: R32, R454B, R1234yf/ze, R134a, R410A, R290, R600a. PPM early warning & %LEL safety, 4–20 mA, RS-485 Modbus, relay outputs. OEM/ODM by Winsen® for bulk orders.
NDIR senzor hladilnega sredstva
Polprevodniški senzor hladilnega sredstva
How Infrared (NDIR) Refrigerant Sensors Work
| Stage | What Happens | Korist |
|---|---|---|
| Emission | IR source emits broadband light through the gas sample. | Reliable optical excitation |
| Filtering | Narrowband optical filter targets refrigerant absorption bands; a second channel serves as reference. | Gas selectivity & drift compensation |
| Detection | Photodetectors measure attenuated signal vs. reference; MCU computes concentration. | Stable ppm / %LEL output |
| Compensation | Temperature/pressure & baseline routines (e.g., ABC optional) correct drift. | Long intervals between calibrations |
Tipične aplikacije

VRF/VRV indoor units & hotel rooms
Montirajte nizko (~150–300 mm AFF) v bližini notranjih enot in točk zbiranja; povezovanje alarmov z zaustavitvijo ventilatorja in odzračevanjem svežega zraka.

Chiller & machinery rooms, compressor racks
Place near compressors, separators, valves, and low spots/sumps; use IP-rated housings and BMS interlocks.

Cold storage & refrigerated display cases
Install beneath cases and along manifolds/pipe runs; choose condensation-resistant designs and curtain/exhaust interlocks.

Podatkovni center v vrsti/CRAC enote
Position in return air, under raised floors, and near coils; ppm early warning protects personnel and uptime.

Heat pumps & general HVAC
For A2L/A3, use %LFL tiers (e.g., ~25% pre-alarm; ~50% main) to trigger ventilation and equipment shutdown.
Infrared vs. Other Technologies
| tehnologija | Najboljše za | Razpon | Prednosti | Premisleki |
|---|---|---|---|---|
| NDIR (infrardeči) | A1 ppm; A2L ppm/%LEL; A3 %LEL (IR-LEL) | ppm → %LEL | High selectivity, low drift, not O₂-dependent | Higher initial cost; protect from heavy condensation/dust |
| MOS (polprevodnik) | A2L/A3 %LEL | 0–100 % LEL | Fast response; cost-effective | Cross-sensitivities; periodic calibration |
| Katalitična kroglica | Splošni ogljikovodiki (A3) | 0–100 % LEL | Mature tech | Needs O₂; can be poisoned (silicones/lead) |
Placement & Setpoints — Good Practice
- Montažna višina: Večina hladilnih sredstev je težja od zraka ⇒ namestite nizko; potrdite s študijami pretoka zraka.
- Pokritost: Approx. 5–10 m radius per sensor in open rooms; add units near valves/joints and low pockets.
- Stopnje alarmov: A2L/A3: pre-alarm ≈25% LFL; main ≈50% LFL. A1: ppm bands (e.g., 1,000–5,000 ppm) per spec.
- Zapore: Pre-alarm → ventilation; Main → equipment shutdown + beacons/BMS alarm.
Dokončajte mejne vrednosti in količine glede na specifikacijo vašega projekta in lokalne kode.
Zakaj nas globalne stranke izberejo?
Podjetje se dosledno drži politike kakovosti »Fine izdelave, znanstvenih inovacij, prizadevanja za odličnost in storitev z dodano vrednostjo«. Z oblikovanjem načrtov vodenja proizvodnih procesov in delovnih navodil je vzpostavil standardiziran, odgovoren in urejen sistem vodenja procesov. Poleg tega je podjetje samostojno razvilo sistem vodenja proizvodnje MES, ki omogoča celovito in vizualno upravljanje celotnega delovnega procesa.

30+ LET IZKUŠENJ
R&D, manufacture and sales of sensors and sensing solutions.
JAMSTVO ZA KAKOVOST STALNO IZBOLJŠEVANJE
Popoln in tog nadzor poteka procesa, skupaj s pomembnimi izboljšavami.


MEDNARODNI TRG
Dostavite izdelke za zaznavanje v več kot 100 držav in regij.
STABILNA DOBAVNA VERIGA ZANESLJIVA PROIZVODNJA
Osrednje komponente, za katere ne veljajo omejitve, napredna oprema za proizvodnjo in testiranje.


R&D STRENGTH TECHNOLOGY INNOVATION
200+ patents, 180+ R&D team members, self-built labs for continous innovation.
Storitev na enem mestu
Strokovno svetovanje, hitra dostava, 24-urna poprodajna podpora.

Leading the Industry, Innovative & Controllable Technology
With robust R&D capabilities, we maintain sustained input in R&D and unwavering commitment to technological innovation. This not only ensures that we remain at the forefront of industry but also drives continuous innovation, leading the future trend of the sensing industry.

10% R&D Input
The average annual R&D input exceeds 10% of the annual revenue.
5+ R&D Layout
With Zhengzhou headquarters as the core, a nationwide R&D and innovation system is being established, encompassing cities of Shanghai, Wuhan, Shenzhen, and Taiyuan.
180+ R&D Team
There are over 180 R&D personnel, including more than 10 with doctoral degrees and over 50 with master's degrees, who have an average of more than 8 years of experience in sensor development.
20+ vrst poskusov
Povezano s plinom, podnebnim okoljem, EMC, električno zmogljivostjo, mehansko zmogljivostjo itd.
10+ naprednih laboratorijev
Laboratorij CNAS, laboratorij MEMS, laboratorij UL, laboratorij za nanokompozitne materiale itd.
400+ sets Leading R&D Equipment
Shranjevanje kock, Die Bonder, Litografski stroj, Stroj za premazovanje, Stroj za polaganje SMT, Avtomatska sondna postaja itd.
Zahtevajte posvetovanje
Pogosta vprašanja — Infrardeči (NDIR) senzorji puščanja hladilnega sredstva
Is NDIR better than MOS for refrigerants?
For ppm early warning and long-term stability, NDIR is typically preferred. For %LEL safety trips on A2L/A3 gases, NDIR-LEL or MOS can both be used depending on budget and environment.
How often do NDIR sensors need calibration?
12–24 months is common with periodic bump tests. High-dust or high-humidity sites may require more frequent checks and filter maintenance.
Where should the sensor be installed?
Near likely leak sources (compressors, valves, joints) and low-lying accumulation points; avoid strong supply air that could bypass the sensor.
Do Winsen IR sensors integrate with BMS/PLC?
Yes—native 4–20 mA, RS-485 Modbus RTU, and relay contacts make integration straightforward.
Can you customize for OEM programs?
Absolutely. We customize ranges, firmware, connectors, harnesses, housings, and branding for volume deployments.















