AC Refrigerant Sensor

AC Refrigerant Sensor (Leak Detector) — Split/VRF • Central AC • Heat Pump

Winsen® electronic AC leak sensors provide continuous, fixed monitoring for air-conditioning refrigerants across residential and commercial buildings. We support A1 (R134a, R410A, R404A), A2L (R32, R454B, R1234yf/ze) and A3 (R290, R600a) gases. Choose Je n za ppm zgodnje opozarjanje oz MOS/IR-LEL for %LEL safety interlocks—ready for BMS/PLC via 4–20 mA, RS-485 Modbusin relejni izhodi.

Pick by Refrigerant Class & Measurement

A1 (R410A / R134a) — NDIR PPM

  • Tipični razponi: 0–1.000 / 0–5.000 ppm
  • Izhodi: 4–20 mA, RS-485 Modbus, 1–2 releja
  • T90 ≤ 30 s • Majhen zanos, dolga življenjska doba

A2L (R32 / R454B / R1234yf/ze) — NDIR PPM / %LEL

  • PPM early warning and/or 0–100% LFL/LEL
  • 4–20 mA / RS-485 / releji
  • VRF/VRV rooms & hotel guestrooms

A3 (R290 / R600a) — %LEL Safety

  • Range: 0–100% LEL (IR-LEL or MOS)
  • Relays for ventilation & shutdown interlocks
  • IP options for plant/mechanical rooms

What is an AC Refrigerant Sensor?

An AC refrigerant sensor is a fixed, electronic detector installed near AC equipment to measure refrigerant concentration and automatically trigger alarms in interlocks (ventilation, unit shutdown). It complements handheld sniffers used by technicians for pinpoint leak search.

NDIR senzor hladilnega sredstva

Polprevodniški senzor hladilnega sredstva

Technology Options

tehnologijaNajboljše zaRazponPrednostiPremisleki
NDIR (infrardeči)A1 ppm; A2L ppm/%LELppm → %LELHigh selectivity & stability; not O₂-dependent; long lifeProtect optics from condensation/dust (filters/enclosures)
MOS (polprevodnik)A2L/A3 %LEL0–100 % LELHiter odziv; robusten; stroškovno učinkovitoPossible cross-sensitivities; periodic calibration advised
Katalitična kroglicaSplošni ogljikovodiki (A3)0–100 % LELMature technologyPotrebuje O₂; se lahko zastrupi s silikoni/svincem

Tipične aplikacije

Split/VRF indoor units & hotel rooms

Mount low (~150–300 mm above floor) near indoor units and pooling points. Pre-alarm → fresh-air purge; main alarm → fan/indoor-unit shutdown.

Central AC (AHU/MAU) & mechanical rooms

Place near coils, TXVs, service valves, and floor low spots/sumps; use IP-rated housings and BMS interlocks.

Line sets & evaporator/condenser sections

Monitor around brazed joints, manifolds; avoid strong supply streams that could bypass the sensor.

Heat pumps

For A2L systems, use %LFL tiers (≈25% pre-alarm; ≈50% main) to trigger ventilation and safe shutdown.

Core Specifications

ParameterVrednost / možnost
MerjenjeNDIR ppm and/or %LFL (MOS/IR-LEL)
Izhodi4–20 mA (2/3-žični), RS-485 Modbus RTU, 1–2 releja (N.O./N.C.)
Odzivni čas (T90)≤ 20–30 s tipično
Dobava12–24 VDC (drugi na zahtevo)
Pogoji delovanja−20…+50 °C; 15–95 % RH brez kondenzacije (odvisno od modela)
OhišjaWall, panel, duct; housings up to IP65
SkladnostCE & RoHS; designed for BMS/PLC integration

Placement & Setpoints — Good Practice

  • Montažna višina: Most AC refrigerants are heavier than air ⇒ mount low; verify with site airflow.
  • Pokritost: ~5–10 m radius per sensor in open rooms; add units near valves/joints and low pockets.
  • Alarmi: A2L/A3: pre-alarm ≈25% LFL; main ≈50% LFL. A1: ppm bands (e.g., 1,000–5,000 ppm) per project spec.
  • Zapore: Pre-alarm → ventilation; Main → equipment shutdown + beacons/horns/BMS event.

Dokončajte mejne vrednosti in količine glede na specifikacijo vašega projekta in lokalne kode.

Zakaj nas globalne stranke izberejo?

Podjetje se dosledno drži politike kakovosti »Fine izdelave, znanstvenih inovacij, prizadevanja za odličnost in storitev z dodano vrednostjo«. Z oblikovanjem načrtov vodenja proizvodnih procesov in delovnih navodil je vzpostavil standardiziran, odgovoren in urejen sistem vodenja procesov. Poleg tega je podjetje samostojno razvilo sistem vodenja proizvodnje MES, ki omogoča celovito in vizualno upravljanje celotnega delovnega procesa.

30+ LET IZKUŠENJ

R&D, manufacture and sales of sensors and sensing solutions.

JAMSTVO ZA KAKOVOST STALNO IZBOLJŠEVANJE

Popoln in tog nadzor poteka procesa, skupaj s pomembnimi izboljšavami.

MEDNARODNI TRG

Dostavite izdelke za zaznavanje v več kot 100 držav in regij.

STABILNA DOBAVNA VERIGA ZANESLJIVA PROIZVODNJA

Osrednje komponente, za katere ne veljajo omejitve, napredna oprema za proizvodnjo in testiranje.

R&D STRENGTH TECHNOLOGY INNOVATION

200+ patents, 180+ R&D team members, self-built labs for continous innovation.

Storitev na enem mestu

Strokovno svetovanje, hitra dostava, 24-urna poprodajna podpora.

Leading the Industry, Innovative & Controllable Technology

With robust R&D capabilities, we maintain sustained input in R&D and unwavering commitment to technological innovation. This not only ensures that we remain at the forefront of industry but also drives continuous innovation, leading the future trend of the sensing industry.

10% R&D Input

The average annual R&D input exceeds 10% of the annual revenue.

5+ R&D Layout

With Zhengzhou headquarters as the core, a nationwide R&D and innovation system is being established, encompassing cities of Shanghai, Wuhan, Shenzhen, and Taiyuan.

180+ R&D Team

There are over 180 R&D personnel, including more than 10 with doctoral degrees and over 50 with master's degrees, who have an average of more than 8 years of experience in sensor development.

20+ vrst poskusov

Povezano s plinom, podnebnim okoljem, EMC, električno zmogljivostjo, mehansko zmogljivostjo itd.

10+ naprednih laboratorijev

Laboratorij CNAS, laboratorij MEMS, laboratorij UL, laboratorij za nanokompozitne materiale itd.

400+ sets Leading R&D Equipment

Shranjevanje kock, Die Bonder, Litografski stroj, Stroj za premazovanje, Stroj za polaganje SMT, Avtomatska sondna postaja itd.

Zahtevajte posvetovanje

    Uspeh! Vaše sporočilo nam je bilo poslano.
    Napaka! Napaka je pošiljala sporočilo.

    WeChat

    Whatsapp

    FAQs — Freon Gas Sensors

    How many sensors are needed in a guestroom or office?

    Plan ~5–10 m radius coverage per sensor in open rooms. Add units near indoor units, valves, joints, and floor-level pockets where gas can accumulate. Irregular layouts typically need more sensors.

    Should I choose ppm or %LEL measurement?

    Use ppm (NDIR) for early warning and comfort/process monitoring; use %LEL (MOS or IR-LEL) to drive safety interlocks for A2L/A3 systems. Many projects deploy both.

    Where exactly should sensors be mounted?

    Most AC refrigerants are denser than air; mount low (≈150–300 mm AFF) near likely leak sources and pooling points. Avoid strong supply air. Duct/return versions can monitor airflow.

    How often do I need calibration and bump tests?

    Typical calibration is every 12–24 months with periodic bump tests (quarterly/biannual). Dusty/humid or aerosol-rich sites may need more frequent checks and filter maintenance.

    What causes false alarms or cross-sensitivity?

    Solvents/aerosols (silicone sprays, alcohol cleaners, paints) can affect semiconductor elements; heavy condensation/dust can obstruct optics. Use IP-rated housings, splash/dust guards, and good placement.

    Can Winsen customize for OEM/volume rollouts?

    Yes—ranges, firmware/Modbus mapping, connectors/harnesses, housings (IP), labels/branding, and packaging are customizable for volume deployments.

    Več znanja o senzorjih hladilnega sredstva

    Ne vem Kateri senzor ima prav?

    Pridobite brezplačno začetno posvetovanje

    je bil dodan v vaš voziček.
    Nakup