Refrigerant Sensor Solution

Winsen Refrigerant Sensor Solution

Refrigerant Sensor Solutions for A2L, R290 and HVAC Leak Detection

Winsen provides refrigerant leak detection solutions for residential air conditioners, heat pumps, commercial HVAC, refrigeration systems and automotive air conditioning. Our product portfolio covers NDIR refrigerant sensors, thermal conductivity refrigerant modules, and semiconductor options for OEM integration.

R32 A2L Detection
R454B Dual-Gas Monitoring
R290 A3 Detection
Is n Selective Detection
OEM Eenvoudige integratie
Tested according to UL 60335-2-40: 2022 & IEC 60335-2-40: 2022 standards
Designed for refrigerant leak detection applications in HVAC and refrigeration equipment.
Winsen refrigerant sensor solution for HVAC and refrigeration systems
Why Detection Matters

A2L and R290 Refrigerants Require Reliable Leak Detection

In HVAC and refrigeration markets, refrigerant selection is moving toward lower-GWP solutions such as R32, R454B and R290. While these refrigerants help improve environmental performance, they also increase the importance of leak monitoring, early warning and system safety design.

Lower GWP Trend R32, R454B and R290 are becoming important choices in air conditioning and heat pump systems.
Veiligheidsclassificatie A2L and A3 refrigerants require appropriate leak detection strategies for equipment safety.
System Protection Fast response and stable monitoring support equipment shutdown, alarm, ventilation or control linkage.
OEM Integration Sensor communication, compact structure and easy wiring are important for HVAC manufacturers.
Refrigerant market trend and safety classification
NDIR refrigerant detection principle
Detectieprincipe

How NDIR Refrigerant Detection Works

NDIR refrigerant detection identifies target gases through their selective absorption of infrared light at specific wavelengths. Refrigerant gas enters the optical chamber, the infrared source emits light, and the detector measures the attenuation signal after the gas absorbs specific wavelengths. This principle supports stable, selective and quantitative refrigerant monitoring.

Selective Detection Snelle reactie Stable Output Suitable for OEM Integration
Portfolio Overview

Complete Refrigerant Detection Product Portfolio

Winsen offers NDIR refrigerant sensor modules for R32, R454B and R290, together with thermal conductivity modules and semiconductor options for different design priorities.

Winsen refrigerant sensor product series
Recommended Products

Refrigerant Sensor Modules for Different Refrigerants and Applications

Use the product groups below to quickly compare suitable modules by refrigerant type, communication method, integration preference and target application.

ZRT512E Refrigerant Sensor Module

Dual-gas NDIR module designed for R32 and R454B refrigerant leak detection in air conditioning and heat pump applications.

ZRT512E refrigerant sensor module

ZRT512E

  • Target Refrigerant: R32 & R454B
  • Principle: Is n
  • Output: RS485
  • Features: Compact design, anti-condensation design, low current design
  • Sollicitatie: Residential AC, heat pump systems

Why Choose ZRT512E?

ZRT512E is suitable when OEM customers need a compact NDIR refrigerant module for R32 and R454B monitoring. It is especially valuable for air conditioning and heat pump systems that require dual-gas coverage, stable communication and convenient controller integration.

R32 & R454B Dual-Gas RS485 -communicatie Compact Structure Anti-condensation Design

ZRT512 Refrigerant Sensor Module

Compact NDIR module for R290 refrigerant leak detection.

ZRT512 refrigerant sensor module

ZRT512

  • Target Refrigerant: R290
  • Principle: Is n
  • Output: RS485
  • Features: Compact size, fast response, stable monitoring
  • Sollicitatie: Refrigerant leak monitoring for R290 systems

Recommended for Compact R290 Leak Detection

ZRT512 is suitable for OEM customers looking for a compact R290 detection module with NDIR selectivity and RS485 output. It supports system integration where size, stability and fast response are important.

R290 Detection NDIR Selectivity Compact ontwerp Reliable Output

ZRT512J Refrigerant Sensor Module

R290 NDIR module with RS485 communication and relay option, suitable for applications that require stronger linkage capability.

ZRT512J refrigerant sensor module

ZRT512J

  • Target Refrigerant: R290
  • Principle: Is n
  • Output: RS485 + relay option
  • Features: Anti-condensation design, stable communication, convenient system linkage
  • Sollicitatie: Heat pumps, commercial HVAC, outdoor-related refrigerant safety designs

Stronger Signal Linkage for R290 Monitoring

ZRT512J is a strong option when the application needs not only refrigerant sensing but also relay-related linkage capability. It is well suited for R290 monitoring where stable system output and practical HVAC integration are required.

R290 RS485 + Relay Option Anti-condensation Design System Linkage

ZRT510E Refrigerant Sensor Module

Horizontal-structure R290 NDIR module designed for compact OEM installation.

ZRT510E refrigerant sensor module

ZRT510E

  • Target Refrigerant: R290
  • Principle: Is n
  • Output: RS485
  • Features: Compact horizontal design, suitable for space-constrained equipment
  • Sollicitatie: OEM refrigerant leak detection integration

For Equipment with Limited Installation Space

ZRT510E is suitable when OEM customers need an R290 NDIR module with a practical horizontal structure for easier installation. It is helpful in compact HVAC and refrigeration designs where space and integration flexibility matter.

Horizontal Structure R290 Detection RS485 Output Compact Integration

ZR210 Thermal Conductivity Refrigerant Detection Module

Thermal conductivity refrigerant detection module for refrigerant leak detection applications.

ZR210 thermal conductivity refrigerant detection module

ZR210

  • Target: Refrigerant detection applications
  • Principle: Thermal conductivity
  • Features: Compact module, practical for OEM integration
  • Sollicitatie: Refrigerant leak monitoring and equipment integration

An Alternative Refrigerant Detection Approach

ZR210 provides a thermal conductivity-based option for refrigerant detection scenarios. It is suitable for customers evaluating alternative refrigerant sensing routes in addition to NDIR-based modules.

Thermal Conductivity Compact Module OEM Integration Refrigerant Leak Detection
Selection Guide

How to Choose the Right Refrigerant Sensor Solution

The best choice depends on refrigerant type, sensor principle, communication requirement, available space, control strategy and application scenario.

Refrigerant sensor selection guide
ModelTarget koelmiddelBeginselUitvoerTypical AdvantagesRecommended Applications
ZRT512ER32 & R454BIs nRS485Dual-gas detection, compact design, anti-condensation designResidential air conditioner, heat pump
ZRT512R290Is nRS485Compact size, selective detection, stable monitoringR290 refrigeration / HVAC safety monitoring
ZRT512JR290Is nRS485 + relay optionBetter linkage capability, anti-condensation designHeat pumps, commercial HVAC, system linkage
ZRT510ER290Is nRS485Compact horizontal structure, easier installationSpace-constrained OEM integration
ZR210Refrigerant detection applicationsThermal conductivityModule-based solutionAlternative detection route, compact moduleRefrigerant leak monitoring integration
Application Scenarios

Suitable for Multiple Refrigerant Leak Detection Scenarios

Winsen refrigerant sensor solutions can be integrated into multiple HVAC and refrigeration applications. Different modules can be matched according to refrigerant type, installation space, communication architecture and control requirements.

Residential Air Conditioner Suitable for R32 / R454B leak detection in home AC equipment.
Heat Pump Reliable refrigerant monitoring for heat pump system safety design.
Commercial Multi-Split / VRF Stable signal transmission for longer-distance and multi-node integration.
Automotive AC Supports refrigerant monitoring in automotive air conditioning scenarios.
Refrigerant sensor application scenarios
Refrigerant safety and standards compliance
Safety & Compliance

Built for Refrigerant Safety Monitoring

For A2L and R290 refrigerant applications, safety is not only about gas detection, but also about stable system response, practical equipment integration and reliable long-term monitoring. Winsen refrigerant sensor solutions are designed for this direction.

A2L Refrigerant Safety R290 Leak Detection Lekdetectie Early Warning Commercial HVAC Koelsystemen
OEM Integration

Flexible Integration for HVAC and Refrigeration Manufacturers

For OEM customers, the value of a refrigerant sensor lies not only in gas detection itself, but also in how easily it can be integrated into the controller, how stable the communication is, whether the module fits the available installation space, and whether the design supports practical HVAC operating conditions.

RS485 -communicatie Compact Structure Anti-condensation Design Low Power Flexible Solution
OEM integration advantages of refrigerant sensors
NDIR vs semiconductor refrigerant detection
Technologie vergelijking

NDIR vs Semiconductor Refrigerant Detection

Different refrigerant detection technologies serve different design goals. NDIR solutions are often preferred when customers need wider operating condition coverage, better selectivity, more stable long-term monitoring and the ability to observe refrigerant concentration output more directly.

NDIR Advantage Higher selectivity, better long-term stability and practical quantitative monitoring capability.
Semiconductor Option Useful where cost-sensitive solutions and fast-response alternatives are preferred.
Frequently Asked Questions

Common Questions from Refrigerant Sensor Projects

Below are some common concerns from HVAC and refrigeration equipment manufacturers when selecting refrigerant detection solutions.

1. What are the advantages of NDIR refrigerant modules compared with semiconductor refrigerant detection?

  • NDIR solutions typically provide better selectivity for target refrigerants.
  • NDIR products are often preferred when customers need more stable long-term operation and concentration-oriented monitoring.
  • For OEM integration, NDIR solutions can be a better fit where system reliability, wide operating conditions and practical leak detection performance are priorities.

2. Which module should I choose for R32 or R454B detection?

  • For R32 and R454B applications, ZRT512E is the recommended product direction on this page.
  • It is especially suitable for residential air conditioner and heat pump refrigerant leak detection projects that need dual-gas capability and compact OEM integration.

3. Which Winsen products are suitable for R290 leak detection?

  • ZRT512, ZRT512J and ZRT510E are the main R290-focused NDIR modules shown on this page.
  • The selection depends on installation structure, communication preferences and whether relay-related linkage support is needed.

4. Can communication baud rate or default address be customized?

  • For customers with special communication requirements, product-side communication settings can be discussed according to the project situation.
  • Please provide your controller interface, communication protocol preference, and integration requirements when sending an inquiry.
Verzoek om raadpleging

Looking for the Right Refrigerant Sensor for Your HVAC or Refrigeration Equipment?

Tell us your refrigerant type, application scenario, controller interface, communication requirement, installation limitation and expected quantity. Winsen can help recommend a suitable refrigerant sensor module or integration direction for your project.

Email: [email protected] Tel: 0086-371-67169097 WhatsApp: +86 175 1317 9603

Niet zeker Welke sensor is gelijk?

Ontvang nu een gratis eerste consult