16Jun
09Jun
Czujniki czynnika chłodniczego na podczerwień do dokładnego wykrywania wycieków w erze czynników chłodniczych o niskim współczynniku GWP
The global HVAC and refrigeration industry is moving rapidly toward low-GWP refrigerants. Refrigerants such as R32, R454B and R290 are increasingly used in residential air conditioners, heat pumps, VRF systems, chillers and commercial refrigeration equipment.This transition supports greener cooling and lower climate impact, but it also brings new...
02Jun
Jak wybrać czujnik czynnika chłodniczego do sprzętu HVAC A2L
Choosing a refrigerant sensor for A2L HVAC equipment is not only a gas-detection decision. It is a system decision tied to refrigerant type, alarm threshold, controller logic, installation position, and long-term reliability. Under UL60335-2-40, refrigerant detection system requirements were refined to improve robustness,...
26May
Moduł czujnika R32 i R454B dla producentów pomp ciepła
As heat pump systems continue to transition toward lower-GWP refrigerants, R32 and R454B have become two of the most important refrigerants in new product development. For manufacturers, this transition is not only about refrigerant replacement. It also changes how the equipment should detect leaks, respond to abnormal concentration, and...
21May
Odliczanie do bezpieczeństwa magazynowania energii: budowanie silniejszej linii bezpieczeństwa za pomocą wykrywania wielowymiarowego
Under the global energy transition, battery energy storage systems are moving from demonstration projects to large-scale grid infrastructure. In China alone, installed new-type energy storage capacity reached 136 GW / 351 GWh by the end of 2025, up 84% from the end of 2024, according to the National...
15May
Wymagania dotyczące czujnika wykrywania czynnika chłodniczego UL 60335-2-40
Wymagania dotyczące czujnika wykrywania czynnika chłodniczego UL 60335-2-40
If you manufacture, specify, or integrate A2L HVAC equipment, the most important point is this: under UL 60335-2-40, the refrigerant detector is not treated as a generic accessory. It is part of a refrigerant detection system (RDS) that includes the...
09May
System wykrywania czynnika chłodniczego (RDS) dla urządzeń R32 i R454B
A refrigerant detection system (RDS) is not just a leak alarm. In A2L HVAC equipment, it is part of the product’s safety architecture: it detects leaked refrigerant at a defined concentration and triggers one or more mitigation actions to reduce hazard. Ashrae defines an...
28Apr
Czujnik wykrywania czynnika chłodniczego A2L dla producentów OEM z branży HVAC
A2L refrigerant detection is no longer just an accessory topic for HVAC manufacturers. As equipment moves from legacy A1 refrigerants toward mildly flammable A2L refrigerants, the detector becomes part of the product’s safety architecture: sensor, logic, mitigation, placement, and lifetime reliability all matter together.
17Apr
Przewodnik po czynniku chłodniczym R-1234yf
R-1234yf: co to jest, dlaczego zastąpił R-134a i co zespoły serwisowe muszą wiedzieć
Co to jest R-1234yf?
R-1234yf, also written HFO-1234yf, is a hydrofluoroolefin (HFO) refrigerant developed mainly for mobile air conditioning (MVAC) as a lower-climate-impact replacement for R-134a. Honeywella’s technical guide lists its chemical...
09Apr